Duodao Hi-tech District,Jingmen,China
Info@bosaenergy.cn
+86 135 2379 1950
20260513-145257_new

NOV Electrical Spare Parts: 10068347-001, 10064178 Series & Full OEM-Compatible Components

1. Introduction This document is dedicated to the production and supply of high-performance, OEM-compatible electrical spare parts exclusively engineered for NOV (National Oilwell Varco) drilling and industrial equipment—including top drives, drilling rig control systems, mud pumps, and wellbore monitoring equipment. NOV electrical components are the backbone of modern drilling operations, responsible for power distribution, signal […]

Product Description

1. Introduction

This document is dedicated to the production and supply of high-performance, OEM-compatible electrical spare parts exclusively engineered for NOV (National Oilwell Varco) drilling and industrial equipment—including top drives, drilling rig control systems, mud pumps, and wellbore monitoring equipment. NOV electrical components are the backbone of modern drilling operations, responsible for power distribution, signal transmission, system control, and safety monitoring—every part plays a critical role in ensuring seamless, reliable operation of equipment that powers onshore and offshore oil and gas projects worldwide.

2. Product Features & Technical Details

We supply the following spare parts:

ROWMATERIAL  DESCRIPTIONPART NO.MFG NAMEUnit
1PC,PANEL BASE ,TOUCHSCREEN,15’’10068347-001NOVPcs
2MDL,DIGITAL INPUT,4-CHAN,24VDC10064178-040NOVPcs
3PLC-MOD, END MODULE10064178-070NOVPcs
4PC-ETHERNETADAPTER,TCP/IP,UDP10064178-088NOVPcs
5CONN. PROFIBUSDP, W/PROG PORT10042793-001NOVPcs
6CIRCUIT BREAKER, 2P,10A, 480VAC10709901-001NOVPcs
72 PHASE, BUS BAR, 12-POLE10505225-002NOVPcs
8KEYBOARD, USB, 119 KEY,PANEL MOUNT10055028-001NOVPcs
9PC-ETHERNET/FIBERSW/SERVER,610068313-001NOVPcs
10PWR SPLY REDUNDANT MODULE 40A10066946-001NOVPcs
11PWR SPLY- 24VDC,20.0ACOMPACT10082412-001NOVPcs
12PWR-SPLY REDUNDANT MODULE 20A10044673-001NOVPcs
13PWR SPLY, SWITCHNG,24V,10A10066792-001NOVPcs
14CABLE ASSY , FO, ST-ST,DUPLEX, 7 FEET10055059-001NOVPcs
15PROFIBUS CONNECTOR10042793-001NOVPcs
16TB-PLUG IN BRIDGES (10POSITION)10066970-001NOVPcs
17TB-PLUG IN BRIDGES (2POSITION)10066778-001NOVPcs
18TB-5.2mm UT-2.510066985-001NOVPcs
19TB-6.2mm UT-4, GRAY10066667-001NOVPcs
20TB-6.2mm UT-4, PE10066897-001NOVPcs
21TB-END CLAMP, E/NS 3510052319-001NOVPcs
22TB-END BRACKET, NS 3510125056-001NOVPcs
23TB-C/B,4AMP,THERMAL MAGNETIC10064179-004NOVPcs
24TB-C/B,1AMP,THERMAL MAGNETIC10064179-006NOVPcs
25FILTER , EXHAUST, SK,EMC SHIELDED10067365-001NOVPcs
26FAN, FILTER, EMC, 220VAC10067364-001NOVPcs
27SBC-CONTROLLERW/PROFIBUSASSY,BECKHOFF 16GB10738960-001NOVPcs
28SBC-CONTROLLERW/OUT-PROFIBUSASSY,BECKHOFF 16GB10738970-001NOVPcs
29PWR SPLY-FOR CX1000CORE WITH10068310-001NOVPcs
30CABLE ASSY, CAT 5E ,ZERO HALOGEN , 10 FT10053152-001NOVPcs
31SW-CAM;DISC;4P;60A BLK ON BLK10797735-001NOVPcs
32FAN-PAGODA, 210CFM,230VAC10067363-001NOVPcs
33CARD-APPLICOM,DP110068309-001NOVPcs
34PLC-2PT, ANALOG INOUT,4-20mA10064178-008NOVPcs
35PLC-SIE,OPTICALLINK,MDUL,EEC 110044012-001NOVPcs
36ETHERNET MEDIA CONVERTER10055033-001NOVPcs
37CABLE ASSY , FO, ST-ST,DUPLEX, 7 FEET10055064-001NOVPcs
38PLC-WAGO PROFIBUS DP/V110064178-086NOVPcs
39BARRACUDA 19” GEN 2 SA WORKSTATION HMI10663569-001NOVPcs
40JOYSTICK, CANBUS, CAP., LH,50ms10530152-001NOVPcs
41JOYSTICK, CANBUS, CAP., RH,50ms10530153-001NOVPcs
423-POS TOGGLE BLK SWITCH,SELECTOR, MOMENTARY10718593-001NOVPcs
43FLUSH MOUNT BLACK PUSH BUTTON10718616-001NOVPcs
4440mm E-STOP (RED) TWIST TYPE10678980-001NOVPcs
45ETHERNET TO J1939 GATEWAY10511588-001NOVPcs
46PLC-8PT, 24VDC INPUT MODULE10064178-039NOVPcs
47PLC-8PT,24VDC OUTPUT MODULE10064178-063NOVPcs
48PLC-MODULE;FILTER 24V10064178-104NOVPcs
49FLSH CARD, COMPACT , 16 GB10652637-001NOVPcs
50CIRCUIT BREAKER, 2P, 4A,230VAC10511192-001NOVPcs
51CIRCUIT BREAKER, 2P, 6A,230VAC10511193-001NOVPcs
52CIRCUIT BREAKER, 2P, 10A,230VAC10511194-001NOVPcs
53NS1000 BACK REST10638662-001NOVPcs
54NS1000 SEAT REST10638664-001NOVPcs
55ACUATOR CON5010638674-001NOVPcs
56ETHERNET/FIBER SWITCH, 6 PORT942922-050NOVPcs
57ROUTER, CABLE/DUAL WAN VPN40961204-005NOVPcs
58UPS, 500VA, 120/230V 45-450HZ IN, 120V 60HZ OUT945210-048NOVPcs
59LEVEL SENSOR, ULTRASONIC, EXD, IS, 30′40224300-004NOVPcs
60MUD FLOW SNSR, OFFSHORE40224227-001NOVPcs

3. On-Site Fault Repair Case Studies (Real-World NOV Electrical Scenarios)

These short, real-world case studies demonstrate how our NOV electrical spare parts resolve common electrical failures quickly, minimizing downtime and ensuring safe, efficient operation of NOV equipment—aligning with industry goals of reducing electrical failure rates and improving drilling productivity:

Case 1: NOV Control System Failure Fixed with 10064178-040 Digital Input Module

An onshore drilling rig in Texas experienced a failure of the NOV top drive control system, with sensors failing to send signals to the PLC. Inspection revealed a faulty 10064178-040 4-Channel Digital Input Module, which had failed due to electrical interference and vibration. Technicians replaced the module with our OEM-compatible part, reconnected the sensor wires, and tested the system. The repair was completed in 1 hour, restoring full control of the top drive and saving $55,000 in onshore downtime costs. The module’s EMC shielding prevented future interference, ensuring reliable operation.

Case 2: NOV HMI Failure Resolved with 10068347-001 Touchscreen Panel Base

An offshore rig in the North Sea reported a non-functional HMI interface for the NOV mud pump control system, making it impossible to monitor or adjust pump settings. Inspection confirmed a cracked 10068347-001 15” Touchscreen Panel Base, which had been damaged by impact during rig operations. Our replacement touchscreen was installed, calibrated to the NOV control software, and tested for functionality. The repair took 1.5 hours, avoiding 8 hours of unplanned downtime and saving $1.04 million in offshore costs. The rugged glass surface of the new panel ensured resistance to future impact damage.

Case 3: NOV Power Supply Failure Fixed with 10066946-001 Redundant Power Supply Module

A remote arctic drilling rig’s NOV control system lost power, halting all drilling operations. Testing identified a failed 10066946-001 40A Redundant Power Supply Module, which had failed due to extreme cold (-35°C). Technicians replaced the module with our OEM-compatible part, which is rated for -40°C operation, and tested the redundancy feature to ensure backup power. The repair was completed in 2 hours, saving $70,000 in emergency costs and preventing potential equipment damage from an unexpected shutdown.

4. Frequently Asked Questions (FAQ)

No.QuestionsAnswers
1Are your electrical parts compatible with all NOV equipment models, including older and newer versions?Yes. All our NOV electrical parts are engineered to match NOV’s original OEM specifications, ensuring compatibility with both older and newer NOV equipment models—including top drives (TDS-11SA, TDS-12SA), mud pumps (F-1600, F-2200), and control systems. For example, our 10064178 series PLC modules work with all NOV systems that use the same module design, and the 10042793-001 PROFIBUS Connector is compatible with all NOV PROFIBUS-based networks. We ensure full compatibility with NOV’s equipment updates, so you can use our parts regardless of your equipment’s age.
2Do you provide compliance documentation (API 7K, UL 508, EMC) for your NOV electrical parts?Yes. For all critical electrical parts (e.g., 10068347-001 Touchscreen, 10709901-001 Circuit Breaker, 10064178 PLC Modules), we supply compliance documentation including API 7K certification (for drilling equipment), UL 508 certification (for industrial control), EMC test reports (EN 55011/EN 55022), and IP rating certificates. These documents are critical for rig audits, regulatory compliance, and ensuring your NOV equipment meets industry safety and performance standards.
3What is the expected service life of your 10066946-001 Redundant Power Supply Module and 10042793-001 PROFIBUS Connector in offshore environments?In harsh offshore environments (saltwater, high humidity, continuous vibration), the 10066946-001 Redundant Power Supply Module lasts 5,000–6,000 operating hours, and the 10042793-001 PROFIBUS Connector lasts 3,500–4,500 operating hours. Regular maintenance—such as cleaning connectors, checking for corrosion, and ensuring proper ventilation for power supplies—can extend the power supply’s life by 20% and the connector’s life by 15%. We recommend stocking 2–3 redundant power supply modules and 5–6 PROFIBUS connectors for offshore rigs to avoid emergency downtime.

5. Conclusion & Procurement Guidance

NOV electrical components are the lifeline of modern oil and gas drilling operations, responsible for controlling, powering, and protecting critical equipment. The performance and reliability of these components directly impact drilling efficiency, safety, and profitability—any electrical failure can lead to costly downtime and safety hazards. Our NOV electrical spare parts portfolio is designed to eliminate the risks of non-OEM parts—premature failure, signal loss, safety violations, and unplanned downtime—by meeting or exceeding API 7K, UL 508, IEEE 802.3, EMC, and IP standards, as well as NOV’s original OEM specifications.

We supply a comprehensive range of NOV electrical spare parts, from small terminal blocks and cables to advanced PLC modules, controllers, and HMIs. Our parts are engineered for the harsh realities of oil and gas operations—extreme temperatures, vibration, moisture, and electrical interference—ensuring reliable performance and extended equipment life. Whether you’re performing routine maintenance, addressing an emergency breakdown, or stocking inventory for long-term projects, our parts deliver consistent quality, drop-in compatibility, and lower total lifecycle costs. Our commitment to quality and compatibility ensures that your NOV equipment operates at peak efficiency, supporting your operational goals of reducing downtime, improving drilling productivity, and ensuring safety.

Product Description