Duodao Hi-tech District,Jingmen,China
Info@bosaenergy.cn
+86 135 2379 1950
20260523-114618_new

GE Industrial Electrical Components: Genuine Replacement Parts for Control & Power Systems

1.Product Introduction This GE electrical parts suite covers five high-demand industrial categories: motor control components (brushes, brush holders, rectifiers, thyristors), PACSystems RX3i PLC modules (CPU, Ethernet, I/O, power supplies), circuit breakers and protection devices (thermal-magnetic breakers, contactors, relays), control hardware (switches, emergency stops, sensors), and generator/exciter parts (field exciters, poles, bearings). All parts are direct-fit […]

Product Description

1.Product Introduction

This GE electrical parts suite covers five high-demand industrial categories: motor control components (brushes, brush holders, rectifiers, thyristors), PACSystems RX3i PLC modules (CPU, Ethernet, I/O, power supplies), circuit breakers and protection devices (thermal-magnetic breakers, contactors, relays), control hardware (switches, emergency stops, sensors), and generator/exciter parts (field exciters, poles, bearings). All parts are direct-fit replacements engineered to match original GE part numbers and system schematics, requiring no on-site modification or rewiring for installation.

2. Key Functional Specifications

  • Motor Control Parts: Carbon brushes, brush holders, and rectifiers designed for 150A-300A generator exciters and heavy-duty motors, ensuring consistent power transmission and minimal sparking at commutation poles.
  • PLC PACSystems RX3i Components: 24VDC power supplies, Ethernet/Profibus communication modules, analog/digital I/O cards, and CPU modules supporting 10/100 Mbps data transfer and 32-point I/O control for industrial automation.
  • Power Protection Devices: Thermal-magnetic circuit breakers (16A-630A), contactors, and 110V protection relays with 50kA short-circuit breaking capacity, safeguarding equipment from overcurrent and short-circuit damage.
  • Control & Communication Parts: Industrial Ethernet switches, emergency stop buttons, and isolation amplifiers ensuring reliable operator control and stable system communication in high-interference environments.

3. Structural & Quality Advantages

  • Global Compliance: All parts meet IEC, UL, IEEE, and CE electrical safety standards, with certified performance ratings for industrial and hazardous location use.
  • Precision Engineering: Electrical contacts and PLC modules undergo strict quality testing, with contact resistance ≤5mΩ and PLC signal accuracy ±0.1% for reliable performance.
  • Durability: Motor brushes feature low-wear graphite formulation (wear rate ≤0.02mm per 1000 hours); circuit breakers have a mechanical lifespan of 10,000+ operating cycles.
  • Plug-and-Play Compatibility: Full cross-referencing with original GE part numbers for seamless replacement of worn components in existing control systems.

4. Applicable Operating Conditions

These GE electrical components are validated for use in demanding industrial environments, performing reliably under these conditions:

  • Operating Voltage: 24VDC control circuits, 110V-400VAC power distribution systems
  • Current Range: 16A to 630A for circuit protection, 150A-300A for generator excitation
  • Environmental Limits: Ambient temperatures -20℃ to 60℃, high-humidity industrial sites, dusty manufacturing facilities, and oilfield drilling platforms
  • Applications: Industrial automation, motor control centers, power distribution panels, generator sets, drilling equipment, and manufacturing production lines

5. Preventive Maintenance & Service Recommendations

Follow these field-proven maintenance steps to extend part life and avoid unexpected GE electrical system failures:

  1. Monthly Checks: Inspect motor brushes for wear (replace if length is below 50% of original), tighten electrical connections, and test circuit breaker trip functionality.
  2. Quarterly Inspections: Clean PLC module contacts and Ethernet ports, check brush holder springs for tension, and verify relay and contactor operation.
  3. Annual Service: Calibrate protection relays, replace worn brush sets and contact tips, update PLC firmware, and test emergency stop devices for proper function.
  4. Component Replacement Guidelines: Replace motor brushes every 8000 operating hours, circuit breakers every 10 years, and PLC communication modules at the first sign of signal interference.

We supply the following spare parts:

ligneCode internedesignationréference
2.2.120282.01144* REDRESSEURIC3500A411DG2
2.2.220282.01266* PORTE BALAI36A160422AAG02
2.2.320282.01272* POLE DE COMMUTATION36A160736AAG01
2.2.420282.01278* BALAIS36A161402AAP3
2.2.520282.01286* BALAIS *36A164453AAP01
2.2.620282.01289* POLE DE COMMUTATION36A163797AFG01
2.2.720282.01298* CHARBONS *36A164452BA001
2.2.820282.01308* PALIER LISSE36C695406AEG01
2.2.920282.01421* POLE DE COMMUTATION893A279ARG03
2.2.1020282.01432* PORTE BALAIS *894A684G4
2.2.1120282.01542* RESSORT DE PORTE BALAIS626B207G1
2.2.1220282.01560* POLE PRINCIPAL36A162376AAG03
2.2.1320282.01630* POLE DE COMMUTATION8842624G1
2.2.1420282.01734* BALAI36A164453BAP01
2.2.1520282.01829* COUSSINET597C992G01
2.2.1620282.01844* INTERRUPTEUR41A251348
2.2.1720282.01963* PALIER SLEEVE BEARING *525D751 HOIEE ACI
2.2.1820282.02166* PORTE BALAI3674563G1
2.2.1920282.02422* BOLT124A9303FR096
2.2.2020282.02734* RESSORT *36B465081AA001
2.2.2120282.02735* RESSORT *36B465082AAG01
2.2.2220282.02736* RESSORT *36B465083AA001
2.2.2320282.03582* AMPLIFICATEUR D’ISOLEMENT17FM394A2
2.2.2420282.03585* BLOC D’ALLUMAGE17FM415A1
2.2.2520282.04055* BALAIS T 90041B535453P6
2.2.2620282.04411* THYRISTOR POUR MOUVEMENT68A7208P20A9239
2.2.2720282.04526* RESISTANCE V.D.R17FM363B1
2.2.2820282.04599* MODULE41A278053G2
2.2.2920282.04608* DIGITAL I/O17FB103B2
2.2.3020282.04961* MODULE EXITATION MOTEUR17FM467D1
2.2.3120282.05101* TYRISTORC155E
2.2.3220282.05463* POLE PRINCIPAL AVEC CIRCUIT MAGNETIQUE ET BARRE DE COMPENSATION36A162357AAG01
2.2.3320282.05493* CARTE ANALOGIQUE17FB140B1
2.2.3420282.05494* CARTE CPU17FB144B3
2.2.3520282.05515* REVERSING CONTACTEUR41A296327AJP1
2.2.3620282.05670* RELAIS DE PROTECTION 110VF650NFBF1G0HIF
2.2.3720282.05799* SWITCH INDUSTRIEL MULTILINKGE-ML1600-HI-A4-A4-XX
2.2.3820282.05984* DISJONCTEUR FIXE FE250 GTM-3P-160A-50KA-400V- IM=800-1600A432971
2.2.3920282.06018* ARRÊT D’URGENCE À COUP DE POING TOURNER POUR DÉVERROUILLER101373
2.2.4020282.06062* DISJONCTEUR FG630 RECORD PLUS430103
2.2.4120282.06063* DISJONCTEUR FG400 RECORD PLUS438432
2.2.4220282.06120* INTERRUPTEUR DIFFERENTIEL BP AC 4P 63 A 300 mA606226
2.2.4320282.06178* BORNIERIC694TBS032
2.2.4420282.06179* CABLE DE RACK D’EXTENSIONIC693CBL300
2.2.4520282.06180* MODULE CHASSIS DE BASE RX3I 16 EMPLACEMENTSIC695CHS016
2.2.4620282.06181* ALIMENTATION 24VDC POLYVALENTIC695PSD140
2.2.4720282.06182* MODULE ETHERNET 10/100 MBITS,2 RJ45IC695ETM001
2.2.4820282.06184* MODULE DE COMMUNICATION SÉRIE, 2 PORTSIC695CMM002
2.2.4920282.06185* KIT RX3I ETHERNET NIU AVEC DEUX MODULES ETHERNETIC695NKT001
2.2.5020282.06186* ENTRÉE DU MODULE TOR 24VDC 32 POINTSIC694MDL660
2.2.5120282.06187* MODULE ENTRÉE ANALOGIQUES, 16 CANAUXIC695ALG626
2.2.5220282.06188* ENTRÉE ANALOGIQUEIC695ALG616
2.2.5320282.06189* MODULE DE SORTIE 0.75A, SORTIE 32 POINTSIC694MDL754
2.2.5420282.06190* PROFIBUS MASTER MODULEIC695PBM300
2.2.5520282.06191* MODULE D’EXTENSION PACS SYSTEMS RX3iIC695LRE001
2.2.5620282.06192* PLAQUE D’EXTENSION D’EXTENSION SÉRIE À 10 EMPLACEMENTS PACSYSTEMS RX3IIC694CHS392
2.2.5720282.06193* ALIMENTATION 24VDC HAUTE CAPACITÉIC694PWR331
2.2.5820282.06194* MODULE DE SORTIE DE TENSION 0,5A, 32 POINTSIC694MDL752
2.2.5920282.06197* FICHE DE TERMINAISON DE BUS ENTREE/SORTIEIC693ACC307
2.2.6020282.06224* DISJONCTEUR674005
2.2.6120282.06225* DISJONCTEUR674001
2.2.6220282.06227* DISJONCTEUR604259
2.2.6320282.06228* DISJONCTEUR604253
2.2.6420282.06229* DISJONCTEUR604251
2.2.6520282.06230* DISJONCTEUR604252
2.2.6620282.06251* DISJONCTEUR MAGNETO-THERMIQUE672279
2.2.6720282.06254* DISJONCTEUR MAGNETO-THERMIQUE674010
2.2.6820282.06255* DISJONCTEUR MAGNETO-THERMIQUE674014
2.2.6920282.06257* DISJONCTEUR MAGNETO-THERMIQUE674029
2.2.7020282.06518* EXCITATEUR DE CHAMP 150A8M13151B0
2.2.7120282.06519* EXCITATEUR DE CHAMP 300A8M13301B0
2.2.7220282.06524* CONTACTEUR41A296327AMP2
2.2.7320282.06527* PROFIBUS NIU NETWORK INTERFACEIC200PBI001
2.2.7420282.06528* POWER SUPPLY 120/240VACIC200PWR102
2.2.7520282.07036* CONTACT3X6660
2.2.7620282.07037* CONTACT3X6659
2.2.7720282.03548* AMPLIFICATEUR IA1-IA217FM390A2
2.2.7820282.01267* PORTE BALAI36A160423AAG01
2.2.7920282.01269* PORTE BALAI36A160427AAG01
2.2.8020282.01290* POLE DE COMMUTATION36A163816ARG01
2.2.8120282.01541* RESSORT DE PORTE BALAIS626B206G1
2.2.8220282.02417* L’NUT124A4934AA024
2.2.8320282.02418* L’WASH124A4935AA024
2.2.8420282.02420* SCREW124A9301BD028
2.2.8520282.02421* SCREW124A9301BD036
2.2.8620282.04598* MODULE41A279579G1
2.2.8720282.04600* PANNEAU17FM384C1
2.2.8820282.04962* MODULE EXITAT ALTERNATEUR17FM466F1
2.2.8920282.05562* PORTE BALAIS D’ALTERNATEUR41B531649G2
2.2.9020282.05622* CONTACTEUR17CM55AH6
2.2.9120282.05798* SWITCH INDUSTRIEL MULTILINKGE-ML2400-F-AC-XX-A4-A4-XX-XX-X
2.2.9220282.01631* POLE PRINCIPAL8842625G1
2.2.9320282.07201* AMPLIFICATEUR D’ISOLEMENT TENSION17FM458A2
2.2.9420492.57672* PANEL RX3IEMERSON REF : IC758CSWB24PC128

6. Field Failure Repair Cases (Real Industrial Scenarios)

Case 1: Motor Brush Wear & Exciter Failure

Issue: A heavy-duty industrial motor experienced intermittent power loss and sparking at the commutation poles, halting production.

Root Cause: Excessive wear on carbon brushes (36A164453AAP01) and weakened brush holder springs, leading to poor electrical contact.

Resolution: Installed genuine GE replacement brushes and new brush holder springs, adjusted brush pressure, and cleaned commutation poles. Normal motor operation was restored within 2 hours, with no further sparking issues.

Case 2: PLC Ethernet Communication Loss

Issue: A PACSystems RX3i control system lost Ethernet connectivity, disrupting automated production line operations.

Root Cause: Faulty Ethernet module (IC695ETM001) with damaged port circuitry, causing data transmission failure.

Resolution: Swapped in a new GE Ethernet module, reconfigured network settings, and tested communication links. Full connectivity was restored, with stable 10/100 Mbps data transfer resuming.

Case 3: Circuit Breaker Overload Trip Failure

Issue: A thermal-magnetic circuit breaker failed to trip during an overcurrent event, damaging downstream electrical equipment.

Root Cause: Worn internal breaker components and degraded trip mechanism, leading to loss of overcurrent protection.

Resolution: Replaced the faulty breaker with a genuine GE unit, tested trip settings, and inspected wiring for damage. Proper overcurrent protection was restored, preventing further equipment risk.

7. Frequently Asked Questions (FAQ)

QuestionAnswer
Are these parts genuine GE replacements for PACSystems RX3i PLCs?Yes, all PLC modules, power supplies, and accessories are genuine GE components, fully compatible with RX3i chassis and systems, with plug-and-play installation.
Do these circuit breakers meet international industrial safety standards?All GE breakers, contactors, and relays comply with IEC 60947, UL 508, and CE standards, with certified short-circuit breaking capacity and overload protection ratings.
Can these motor brushes fit GE industrial generators and exciters?Yes, these carbon brushes and brush holders are engineered specifically for GE 150A-300A field exciters and heavy-duty motors, matching OEM dimensions and performance specs.

8. Procurement Guidance & Call to Action

For industrial facilities, power plants, and drilling operations relying on GE electrical control and power systems, securing genuine, high-quality replacement parts is critical to minimizing unplanned downtime, maintaining operational efficiency, and upholding electrical safety standards. This parts list serves as a definitive procurement standard and technical reference, simplifying your sourcing process for emergency repairs, scheduled maintenance, and full system overhauls.

Product Description