Detailed Product Introduction

This Rig 23 electrical parts collection covers all mission-critical electrical subsystems: HVAC components (Copeland scroll compressors, Toshiba/Genteq fan motors, Eaton/Furnas contactors, expansion valves), VFD and control modules (Lenze SF530 VFD, Siemens 6ED1 LOGO! controllers, ABB/GE/Eaton circuit breakers), HPU PLC components (Siemens S7-200 PLC modules, industrial fuses), rig safety parts (explosion-proof LED flood lights, foot switches), UPS systems (APC 1000VA/2000VA units), and communication cabling. Each item is cross-referenced to Rig 23’s OEM part numbers, voltage ratings, and equipment model numbers, ensuring perfect drop-in fit and zero compatibility errors.
Functional Performance & Value Highlights
- Eliminate Rig Electrical Downtime: OEM-matched electrical parts cut diagnostic and replacement time by 65%, preventing costly drilling shutdowns from HVAC or VFD failures.
- 100% Voltage & Phase Compatibility: Pre-tested components match Rig 23’s 575V/3PH, 208-230V/1PH power systems, eliminating short circuits and component burnout.
- Enhanced Electrical Safety: Industrial-grade breakers, contactors, and explosion-proof LED lights comply with rig electrical safety codes, reducing fire and shock hazards.
- Long-Term Durability: Heavy-duty motors, capacitors, and VFD parts resist vibration and temperature extremes, extending service life by 50% compared to generic replacements.
Structural & Engineering Features
- Rig-Specific Drop-In Fit: Exact dimensional and electrical matches for Rig 23’s OEM equipment, no wiring modifications or adapter parts required for installation.
- Environmental Sealing: HVAC motors and electrical components feature dust/moisture resistance, suitable for harsh rig environments with high humidity and debris.
- Standardized Electrical Ratings: All contactors, breakers, and fuses have clearly marked voltage, amperage, and phase ratings for quick identification and safe installation.
- Modular Design: Plug-and-play control modules, PLC components, and contactors simplify on-site repairs, even with limited technical labor.
Applicable Operating Conditions
- These Rig 23 electrical parts are engineered for harsh drilling rig environments where reliable electrical performance is critical, including:
- Onshore and offshore drilling rigs with 575VAC/3PH and 208-230VAC/1PH power distribution
- Enclosed rig spaces (Driller Cabin, SCR House, VFD House) with temperature control requirements
- Hazardous location rig areas requiring explosion-proof lighting and electrical components
- 24/7 continuous rig operations with high electrical load demand
- Remote rig sites with limited access to replacement electrical parts
Professional Maintenance & Troubleshooting Recommendations
- Pre-Installation Voltage Check: Verify incoming power voltage matches component ratings (575V/3PH, 208-230V/1PH) to prevent immediate component failure.
- Contactor & Breaker Inspection: Test contactor coil resistance and breaker trip amperage before installation to ensure proper load protection.
- HVAC Motor Lubrication: Lubricate fan motor bearings per OEM specifications before installation to reduce friction and extend motor life.
- VFD & PLC Programming Check: Confirm control module firmware and wiring diagrams match Rig 23’s existing systems to avoid operational errors.
- Scheduled Electrical Testing: Test breakers, fuses, and contactors every 90 days to identify wear before catastrophic failure occurs.
We supply the following spare parts:
| Description | Specification / Model | ||
| Air Conditioner Damage Part List | |||
| Driller Cabin (Custom Control Company, MODEL # HACAB72-PV42-4-RMF, JOB A3831-2 ) | |||
| 1 | COMPRESSOR | COMP MODEL # ZR61KCE-TFE-950, MAKE- COPELAND SCROLL, 575 VAC, 60 Hz, PH-3, LRA-49.0; | |
| 2 | CONDENSER FAN MOTOR | MODEL # 6K5001L 32VA2AG, 575 VAC, 60 Hz, HP-1, AMPS-1.5, RPM-1170, PH-3, FRAME SIZE-145T. MAKER-TOSHIBA | |
| 3 | INDOOR FAN MOTOR | K55HXPYB-1750; 1/3HP, 2.0/2.2AMP, 1PH, 208-230VAC, 1100/925RPM. US MOTORS | |
| 4 | CAPACITOR | 27L5018, 10uf±6%, 370VAC, 50/60Hz; GENTEQ | |
| 5 | CONTACTOR | DIM M10-12, XTCE012B10, COIL: 24VAC, 50/60Hz, EATON | |
| 6 | CONTACTOR | DIL EM-10; XTMC9A10; COIL: 24VAC, 50/60Hz, EATON | |
| 7 | OVERLOAD RELAY | ZE-1.6 XTOM1P6AC1; EATON | |
| 8 | CONTACTOR | C25BNB225T, COIL: 24V, 25A, 277VAC, 60Hz, EATON | |
| 9 | EXP MODULE | 6ED1 055-1HB00-0BA0; | |
| 10 | CONTROLLER | 6ED1 055-1HB00-0BA6; | |
| 11 | VFD | SF530; 480/590V, 50/60Hz, 3ph,4.7A; Output: 0-460-575Vac; Make: LENZE AC TECH; | |
| Dog House | |||
| 1 | Ex-SPLITER A/C | MODEL # BBKT-45/G1, A/C,EX-PROOF HIGH TEMPERATURE SPILTER WALL MOUNTED,4500W,208V/60Hz;. | |
| Top Drive VFD House | |||
| 1 | A/C UNIT | AVP60ACG09NU-1000G, MAKE- MARVAIR, 208/230 VAC, 60 Hz, | |
| 2 | COMPRESSOR | CRNQ-050E-TF5-970; 200-230VAC, 3PH, 60Hz. MAKE-Copeland; | |
| 3 | INDOOR FAN MOTOR | F48H82B81; 3/4HP, 1120RPM, 230V,1PH, 50/60Hz; CAP10, MFD/370V; | |
| 4 | CONDENSER FAN MOTOR | YSLB-220-8-B001; 1/4 HP 230V; 825RPM; MAKE: OEM Interlink; | |
| SCR House (Model # ZF120C00B5A1AAA1A1, MAKE-YORK.) | |||
| 1 | COMPRESSOR | HLH068T7LC6; 575V, 3PH, 60Hz, LR:62.0A; | |
| 2 | INDOOR FAN MOTOR | MODEL: 5K49TN4282CX, 2HP, 575V, 3PH / 60HZ, 1725RPM, 2.4A, SF:1.2 , SFA: 2.8 | |
| 3 | CONDENSER FAN MOTOR | MODEL: F48T71A50; 1PH, 60HZ, 575V, 3/4HP, CAP10.0 MFD/440VAC, 1110RPM, Genteq. | |
| 4 | EXPENSION VALVE | UPG PN: 992892; TR6, R410A; PS45.5bar / 660PSIG; BC4415F. | |
| 5 | CONTACTOR | 365030; 30FLA, 40AMP, 600V; COIL: 24VAC, 50/60Hz; | |
| 6 | CONTACTOR | 42CF35AJ, PN: 61445; MAKE- Furnas. | |
| 7 | BELT | A-55; 13X1400; DONGIL SUPER STAR. | |
| 8 | CAPACITOR | Z50P4410M; 141375 SH 0304; 10uF,440Vac, 50/60Hz; MAKE-Aerovox | |
| 9 | CAPACITOR | 10uf±6%; 440VAC/B, 50/60Hz, MAKE-CSC | |
| No. | Description | Specification / Model |
| TOP DRIVE VFD HOUSE | ||
| 1 | ABB breaker | S401 M C16 |
| 2 | GE.Spectra RMS. CURRENT LIMITING CIRCUIT BREAKER | Cat。NO. SELA36AT0060 60Amp Max |
| 3 | AB .PILOT LIGHT LAMP | CM755-27 |
| 4 | ETN BREAKER | XTPR012BC1 In=12A |
| 5 | ETN BREAKER | XTPR6P3BC1 In=6.3A |
| 6 | ETN OVERLOAD RELAY | XTCEXFAC22 |
| 1 | PLC MODULE | 6ES7 214-IBD20-0XB0 PLC S7-200 |
| 2 | FUSE | P/N: 0000-6986-06 FUSE.GDC-2A.250V.5*20MM |
| 3 | FUSE | P/N: 0000-6942-94 FUSE-250.MA.250V C.KIC. |
| 4 | FUSE | P/N: 0000-6966-92 FUSE-20.A,600VAC,200KIC.T |
| 5 | FUSE | P/N: 0000-6895-88 FUSE-6A,600V C,200KIC |
| 6 | CONTACTOR | P/N: 0000-6979-51 CONTR-18A,4P,575VAC,120VAC |
| 7 | OVERLOAD RELAY | P/N: 0000-6979-40 RLY-OL 10.0-16.0 A,ALLEN |
| 1 | FOOT SWITCH | GTRFP6419-007; Foot Switch; |
| 1 | Ex-LED Flood Lights | HPLN-25L-C3-20C-W; 120-277V AC LED= (750W-1000W) Flourescent Lamp, (W/Safety Chain,Beam Clamps, cable gland & Angle Bracket) |
| UPS | ||
| 1 | TP/Company Man Office UPS | 1000VA, 230V/50/60HZ, APC |
| 2 | Instrumentation System UPS | 2000VA, 110V/50/60HZ, APC |
| FEESTON | ||
| 1 | Coaxial cable | 1C, MD TOTCO |
On-Site Rig Electrical Fault Repair Cases
Case 1: Driller Cabin HVAC Compressor Failure
Rig 23’s Driller Cabin (HACAB72-PV42-4-RMF) lost cooling due to a failed Copeland ZR61KCE-TFE-950 scroll compressor, halting cabin operations. Replacing the compressor with the OEM-matched unit restored 575V/3PH cooling functionality, resuming driller operations within 3 hours.
Case 2: Top Drive VFD Breaker Trip
The Top Drive VFD House experienced repeated overload trips due to a faulty ABB S401 M C16 breaker. Swapping the defective breaker with the OEM replacement restored stable VFD power, eliminating unexpected top drive shutdowns.
Case 3: SCR House Fan Motor Burnout
York ZF120C00B5A1AAA1A1 SCR House overheating occurred from a failed Genteq F48T71A50 condenser fan motor. Installing the OEM 575V/1PH fan motor fixed airflow and cooling, preventing SCR system overheating and downtime.
Frequently Asked Questions (FAQ)
| Question | Answer |
| Are these electrical parts only compatible with Rig 23’s specific equipment models? | Yes, these parts are precision-matched exclusively to Rig 23’s HACAB72-PV42-4-RMF driller cabin, York ZF120C00B5A1AAA1A1 SCR house, and dedicated VFD/HPU systems. Compatibility with other rig models is not guaranteed. |
| Do these electrical components meet rig industrial safety and voltage standards? | Absolutely. All breakers, contactors, and explosion-proof lights comply with industrial electrical safety standards, and every part is rated for Rig 23’s 575VAC/3PH and 208-230VAC/1PH power systems. |
| Can I use these parts for both emergency repairs and routine maintenance? | Yes, this catalog includes parts for urgent fault repairs (compressors, breakers) and routine upkeep (capacitors, fan motors, fuses) for all Rig 23 electrical subsystems. |
Procurement Guidance & Call to Action
For Rig 23 electrical maintenance teams, drilling supervisors, and procurement specialists managing critical rig electrical systems, this parts list is the definitive resource to minimize downtime, ensure safety compliance, and source guaranteed OEM-compatible electrical components. Avoid the risks of generic part incompatibility, electrical failures, and costly drilling shutdowns — this catalog serves as both a standardized procurement blueprint and technical diagnostic reference for all Rig 23 HVAC, VFD, control, and power distribution components.
Secure these Rig 23-specific electrical parts to execute fast, reliable on-site repairs, maintain consistent HVAC and power system performance, and uphold the highest electrical safety standards for your drilling operations. Each component is built to withstand the rigors of 24/7 drilling use, making this the trusted choice for keeping Rig 23’s electrical systems operating efficiently and safely.