Product Introduction

This collection features genuine-equivalent NOV TDS electrical parts, spanning circuit breakers (CB-16AT, E3 series 1600AF/800AF), rectifiers, VFD inverter modules, fuses, contact blocks, power supplies, metering devices, and control PCBs. Each part is manufactured to replicate OEM form, fit, and function, with strict quality testing for high-amperage, high-voltage drilling environments. Covered part families include CB thermal-magnetic breakers, UVR (undervoltage release) coils, auxiliary contacts, DC power supplies, rectifier fan PCBs, and Profibus communication modules—all tailored for TDS drilling top drives.
Functional Capabilities
- Power Distribution & Protection: Circuit breakers and fuses deliver overcurrent, short-circuit, and undervoltage protection (6kIC–75kIC interrupt ratings), safeguarding TDS power trains and sensitive control electronics
- Motor Control & Variable Speed Regulation: VFD/inverter components (500KW drive modules, precharge boards) enable precise top-drive motor speed control, optimizing drilling torque and efficiency
- Voltage Conversion & Rectification: 3-phase rectifiers (2700A, 690V) and transformers (2KVA, 500VA, 150VA) convert AC to DC power and regulate voltage for TDS control circuits
- System Monitoring & Metering: Digital meters (KW, KVAR, AAC) and hour meters track real-time power usage, runtime, and operational performance for preventive maintenance
- Ground Fault & Sync Detection: Ground detection modules and sync check cards ensure safe rig operation, preventing electrical hazards and phase misalignment
Structural & Design Features
- DIN Rail & Panel Mounting: Compact, industry-standard mounting designs for easy installation in TDS control cubicles (600MM fixed breaker enclosures, vertical stabilizer kits for 3200A breakers)
- Lockout/Tagout Compatibility: Padlock covers and operator buttons enhance OSHA-compliant lockout procedures during maintenance
- Modular PCB Design: Plug-and-play control boards (rectifier fan power supply, motor control units) reduce repair time and simplify component replacement
- High-Current Termination: Heavy-duty terminal blocks (30-pin, 2-pin) support 26–10AWG wiring, handling maximum current loads without overheating
- Environmental Sealing: Rugged construction resists oilfield dust, moisture, and mechanical vibration, extending service life in extreme conditions
Applicable Operating Environments
These electrical parts are engineered foronshore and offshore drilling rigs operating in extreme industrial conditions, with certified performance for:
- Voltage ranges: 24VDC–690VAC, 1000VDC
- Current ratings: 0.6A–3200A
- Temperature ranges: -40°C to 85°C (industrial operating threshold)
- High-vibration, high-dust oilfield environments
- Fixed and mobile TDS top-drive systems (1600A generator/feeder cubicle configurations)
Preventive Maintenance Recommendations
- Regular Inspection Schedule: Conduct visual and electrical testing every 3 months to check for loose terminals, burnt contacts, and fuse degradation; document meter readings and breaker trip history
- Component Replacement Intervals: Replace wear-prone parts (fuses, contact blocks, surge suppressors) annually or after 2000 operating hours; replace circuit breakers and rectifiers every 5 years or post-fault
- Environmental Protection: Keep control cubicles sealed and dust-free; apply dielectric grease to terminal connections to prevent corrosion in humid offshore environments
- Calibration Checks: Recalibrate power meters and voltage transducers every 6 months to ensure accurate monitoring and compliance with industrial standards
- Spare Inventory Management: Stock critical fast-moving parts (fuses, CB auxiliary contacts, relays) on-site to minimize downtime during emergency repairs
We supply the following spare parts:
| Incomer / Rectifier | ||||
| 1 | 10040321-001 | NOV | CB-16AT,2P, 240VAC, KIC, 63AF | PZA |
| 2 | 10066977-001 | NOV | CB-MINATURE,1A,240V,2P,DIN x 1 | PZA |
| 3 | 10064179-004 | NOV | CB-C/B,4AMP,THERMAL-MAGNETIC x 3 | PZA |
| 4 | 10633702-001 | NOV | B-PB PADLOCK COVERS,4/ EATON x 1 | PZA |
| 5 | 10633696-001 | NOV | B-UVR(YU),120VAC,4/ EATON MAG x 1 | PZA |
| 6 | 10633704-001 | NOV | CB-AUX CONTACTS, 2a/2b,4/ EATON x 2 | PZA |
| 7 | 10633701-001 | NOV | CB-CHARGING MOTOR,120VAC,4/EATON x 1 | PZA |
| 8 | 10633706-001 | NOV | CB-KIT,VERTICAL STAB,3200A,4/EAT x 1 | PZA |
| 9 | 10636263-001 | NOV | DSW-DC,3P,2500AF,IEC,FIXED,HR x 1 | PZA |
| 10 | 10042480-014 | NOV | FUSE-30. A,1000VDC/100KAIC x 4 | PZA |
| 11 | 10067465-001 | NOV | FUSE-HOLDER,2P,30A,600/690VAC, x 2 | PZA |
| 12 | 10067627-001 | NOV | METER-VDC,0-1200,10VDC INPUT x 1 | PZA |
| 13 | 10040885-001 | NOV | CONT-BLK,0A1B0C,OT,RED x 1 | PZA |
| 14 | 10049864-001 | NOV | PB-CAP, ,PDLCK ATCHMNT x 1 | PZA |
| 15 | 10040874-001 | NOV | PB-OPER,RED,STOP,F/8000 LINE x 1 | PZA |
| 16 | 10812641-001 | NOV | PCB – RECTIFIER FAN PWR SUPPLY (View) x 1 | PZA |
| 17 | 10066883-001 | NOV | WR SPLY- 24V , 5. A,INPUT x 1 | PZA |
| 18 | 10719558-002 | NOV | RECT-3PH,690V,2700A,DUAL TEMP SW (View) x 1 | PZA |
| 19 | 10042140-001 | NOV | RELAY 24VDC 4AOBOC 10 A x 1 | PZA |
| 20 | 10635356-001 | NOV | CB-TIME DELAY UVR,120VAC,4/EATON x 1 | PZA |
| Inverter / VFD | ||||
| 21 | 10044443-001 | NOV | BRANCHING UNIT,APBU,ABB x 1 | PZA |
| 22 | 10066238-001 | NOV | CB- 5AT;2P;480Y/277VAC;6KIC x 1 | PZA |
| 23 | 10633698-001 | NOV | CB-CLOSING COIL,120VAC/DC,4/ EATON x 1 | PZA |
| 24 | 10635351-001 | NOV | CB-LATCH CHECK SWITCH,4/EATON x 1 | PZA |
| 25 | 10633571-001 | NOV | DSW-DC,3P,2000AF,IEC,FIXED,HR x 1 | PZA |
| 26 | 10067463-001 | NOV | FUSE-1600A,690VAC/700VAC,IEC x 4 | PZA |
| 27 | 10909468-001 | NOV | INVERTER-500 KW,500V,700A,AIR x 2 | PZA |
| 28 | 10044564-001 | NOV | ANEL-AC DRIVE CONTROL PANEL x 1 | PZA |
| 29 | 10040884-001 | NOV | CONT-BLK,1A0B0C,OT,GRN x 1 | PZA |
| 30 | 10040873-001 | NOV | PB-OPER,BLK,STOP,F/8000 LINE x 1 | PZA |
| 31 | 10703252-001 | NOV | PCA-DC PRECHARGE / VFB BOARD B (View) x 1 | PZA |
| 32 | 10044530-001 | NOV | MODULE-FIBER,DDCS ACS800 x 1 | PZA |
| 33 | 10044446-001 | NOV | PC BOARD-MOTOR CONTROL UNIT FOR ACS800 | PZA |
| 34 | 10042138-001 | NOV | RLY-120VAC,4A0B0C, 10A,IEC x 1 | PZA |
| 35 | 10042086-001 | NOV | SUPPRESSOR-SURGE, 72-240VAC x 1 | PZA |
| 36 | 10044500-001 | NOV | BOARD-PROFIBUS MODULE,ABB x 1 | PZA |
| 37 | 10045092-001 | NOV | B-CONTACT BLOCK 1NO x 4 | PZA |
| 38 | 10517436-001 | NOV | CONTACT BLOCK x 1 | PZA |
| 39 | 10517427-001 | NOV | W 2 POSITION,MAIN,NON ILLUMIN x 1 | PZA |
| 40 | 10517441-001 | NOV | W PADLOCK x 1 | PZA |
| Generator Cubicle | ||||
| 41 | 10541038-001 | NOV | MODULE AC – STANDARD WITH ADDED | PZA |
| 42 | 10068069-001 | NOV | 300 VA; 480:120V;PT | PZA |
| 43 | 10050546-001 | NOV | XFMR- 2KVA,480/240:120 ,CPT | PZA |
| 44 | 10050545-001 | NOV | XFMR-140VA,480 :115 ,CPT | PZA |
| 45 | 10043864-001 | NOV | XFMR-500VA,600:120,50/60HZ,CPT | PZA |
| 46 | 10040783-039 | NOV | FUSE- 15. A, 500V C, 10KIC | PZA |
| 47 | 10041043-042 | NOV | FUSE- 30. A, 600V C,200KIC,C | PZA |
| 48 | 10067603-001 | NOV | LIGHT-ENCLOSURE,FLUORESCENT | PZA |
| 49 | 10049350-001 | NOV | PB-KIT; A B C;3HD OFF-IDLE-RUN | PZA |
| 50 | 10049837-001 | NOV | CONT-BLK;1A0B0C;600VAC | PZA |
| 51 | 10040541-001 | NOV | BDGE-30V, 1000V, 1PH | PZA |
| 52 | 10050053-001 | NOV | PC-GEN EXC;REV 120 OR 240V | PZA |
| 53 | 10062877-001 | NOV | TB- 30 PIN,26-10AWG,EX,UTTB4 | PZA |
| 54 | 10060967-001 | NOV | TB-2 PIN,26-10AWG,EX,UT4 | PZA |
| GEN-1600 (CT&METER) | ||||
| 55 | 10800750-023 | NOV | METER-KW,0-1600,96MMDIN,0-1MADC | PZA |
| 56 | 10800750-022 | NOV | METER-KVAR,0-1600,96MMDIN,0-1MADC | PZA |
| 57 | 10800750-001 | NOV | METER-AAC,0-2000,96MMDIN,0-1MADC | PZA |
| 58 | 10517665-001 | NOV | METER-HOUR METER,120VAC,DIN | PZA |
| GEN-1600CB,FIX,75KA,TOP,600MM | ||||
| 59 | 10049527-044 | NOV | CB-1600AF,E3,3P,690VAC, 75KIC | PZA |
| 60 | 10049599-001 | NOV | CB-UVR(YU),120VAC/DC,FOR E1 TH | PZA |
| 61 | 10051296-001 | NOV | CB-CLOSING COIL,120VAC/VDC | PZA |
| 62 | 10688832-001 | NOV | PLATE-COVER FOR ABB E3 BREAKER | PZA |
| GND DETECTION,HOC,MOV,SYNC-LAND,480V | ||||
| 63 | 10067495-001 | NOV | PL-TERMINAL COVER FOR SCREW | PZA |
| 64 | 10077591-001 | NOV | PL- 24VAC/DC,25MM,GRN LED,LW | PZA |
| 65 | 10041157-001 | NOV | MOV- 750 VRMS | PZA |
| 66 | 10041444-006 | NOV | FUSE- 200. A, 1250V C,100KIC | PZA |
| 67 | 10697876-001 | NOV | XFMR- 150VA, 480:120V,PT,1PH | PZA |
| 68 | 10534211-001 | NOV | CB-2AT, SLO, 1 AUX,1P,2.5KA@250V | PZA |
| 69 | 10041043-009 | NOV | FUSE- .6A, 600V C,200KIC | PZA |
| 70 | 10785240-001 | NOV | FUSE-HOLDER,3P, 30A, 600V C | PZA |
| 71 | 10050074-001 | NOV | PC-SYNC CHECK AND CHG CARD | PZA |
| 72 | 10050555-001 | NOV | XFMR- 50VA,480 : 31V,CPT | PZA |
| 73 | 10531564-005 | NOV | CB-5AT, SLO, 1 AUX,2P,2.5KA@250V | PZA |
| 74 | 10050044-001 | NOV | RLY-120AC 2PDT & BASE | PZA |
| Feeder Cubicle | ||||
| 75 | 10049527-044 | NOV | CB-1600AF,E3,3P,690VAC, 75KIC | PZA |
| 76 | 10924349-001 | NOV | CB-800AF,E3,3P,690VAC, 75KIC | PZA |
| 77 | 10049598-001 | NOV | CB-UVR(YU),24VDC,FOR E1 THRU | PZA |
| 78 | 10065513-001 | NOV | CB-OVERCURRENT TRIP INDICATOR | PZA |
| 79 | 10688832-001 | NOV | PLATE-COVER FOR ABB E3 BREAKER | PZA |
| 80 | 10043864-001 | NOV | XFMR-500VA,600:120,50/60HZ,CPT | PZA |
| 81 | 10534209-001 | NOV | CB-5AT, SLO, 1 AUX,1P,2.5KA@250V | PZA |
| 82 | 10534205-001 | NOV | CB-3AT,SLO,1P,W/INTER DLY,1AUX | PZA |
Field Troubleshooting: Real-World Failure Cases
Case 1: CB-16AT Circuit Breaker Tripping Without Load
A land drilling rig experienced repeated nuisance tripping of the 16AT 2P circuit breaker (part 10040321-001) in the incomer module. Diagnosis revealed a faulty undervoltage release (UVR) coil and worn auxiliary contacts. Replacing the UVR coil (10633696-001) and auxiliary contact block (10633704-001) restored stable operation, eliminating unplanned tripping and 8+ hours of downtime.
Case 2: VFD Inverter Communication Failure
An offshore rig’s 500KW VFD inverter (part 10909468-001) lost Profibus communication, disabling top-drive speed control. Technicians identified a faulty Profibus module (10044500-001) and fiber optic module (10044530-001). Swapping the damaged control boards restored communication, resuming drilling operations within 4 hours.
Case 3: Generator Cubicle Fuse Bank Failure
A 1600A generator cubicle experienced a 30A fuse (10041043-042) blowout due to overcurrent. The fuse holder (10067465-001) showed signs of overheating, indicating a loose terminal connection. Tightening terminals and replacing the fuse bank and holder prevented repeat failures and avoided a full system shutdown.
Frequently Asked Questions (FAQ)
| Question | Answer |
| Are these parts compatible with all NOV TDS top-drive models? | Yes, these components are designed to fit standard NOV TDS drilling top drives, matching OEM electrical ratings, mounting dimensions, and connector specifications for seamless replacement. |
| What is the short-circuit withstand rating for the E3 1600AF circuit breaker? | The 1600AF E3 circuit breaker (10049527-044) features a 75kIC short-circuit interrupt rating at 690VAC, meeting IEC industrial safety standards for high-power drilling systems. |
| Can these parts be used for both preventive maintenance and emergency repairs? | Absolutely. These parts are ideal for scheduled preventive maintenance to avoid failures and for emergency field repairs to minimize downtime, with plug-and-play designs for quick installation. |
Procurement Guidance & Value Proposition
For drilling operations prioritizing reliability, compliance, and minimal downtime, these NOV TDS electrical parts are the definitive procurement choice. By selecting these OEM-equivalent components, you eliminate the risks of substandard aftermarket parts, reduce long-term maintenance costs, and ensure consistent performance of critical TDS electrical systems. Every part is engineered to strict industrial standards, with verified electrical ratings and durability for harsh oilfield conditions, making this catalog your go-to reference for both planned inventory stocking and urgent replacement needs.
Whether you are sourcing circuit breakers, rectifier components, VFD modules, or metering devices, this listing provides clear, accurate specifications to streamline purchasing decisions and technical troubleshooting. Secure high-quality, performance-matched electrical parts to keep your TDS drilling equipment operating at peak efficiency, reduce costly downtime, and maintain strict safety and compliance standards in every drilling operation.